The OCD range of heavy duty steam generators is designed for trouble free continuous use for up to 16hours in commercial environment such as a spa, gym or hotel. The advanced control system allows scheduled programming to activate the generator at different times during the day for a fully automated operation. The descaling cycle can also be programmed to run at a set time during the week to ensure the tank is kept free from limescale buildup. The large bore drain valve has easy access cap for easy removal of any limescale deposits. The LCD display has detailed diagnostics also allows lighting and fan to be switched via generator.
Specifications
| OUTPUT | 9Kw |
| DIMENSIONS (LXWXH) | 610mm x 300mm x 585mm |
| CONTROLLER | OCD digital controller |
| ELECTRICAL SUPPLY | 230/400 Volt |
| HIGH DENSITY ROOMS (STONE/CERAMICS) M³ | 6-8 |
| LOW DENSITY ROOMS (PLASTIC/LAMINATES) M³ | 7-11 |
| NUMBER OF ELEMENTS | 2 x 4.5Kw |
| WATER CONSUMPTION LTRS/HOUR | 11.25 |
TEFLON COATED INCALLOY ELEMENTS
Oceanic Steam generators are fitted with powerful long life elements specially coated to help resist build up of limescale. Heating elements are easy to replace and can be bought individually or in discounted sets via the website.
SEQUENTIAL HEATING
From cold both elements operate for rapid heating, when the room temperature is almost reached some of the elements are turned off and the required temperature is achieved by alternating power to the remaining elements to gently maintain the temperature without large fluctuations improving user comfort.
MULTIPLE GENERATOR CONTROL
Two or more generators can be linked together for larger steam rooms.
EASY TO USE DIGITAL CONTROLS
A simple to operate water resistant digital control pad can be installed inside or outside the steam room disaplying the time and temperature settings. A temperature sensor located inside the room is linked to the system providing accurate control up to 60oC for up to 240minutes of continuous use. A series of LEDs provide real time diagnostics for all of the generators functions and a light within the room can also be switched via the keypad.
AUTO DRAIN AND FLUSHING
All generators feature an auto drain down with a self flushing cycle to dump the boiler contents in a controlled manner. At the end of each steaming session the generator will stop for a few minutes to allow the water to cool a little then the drain valve will open and after a short time the cold water inlet valve will open to give a period of continuous flushing and draining.Flushing and draining the boiler reduces the build up of damaging limescale, cooling the elements before the final drainage helps prolong their useful life.
AUTO DESCALE
To ensure long life of a commercial steam generator running continuously throughout the day the auto descale feature is essential. From the keypad you can choose which day and time you want the descaling cycle to take place (for example Sunday 00:00 - 7:00). The generator is supplied with a pump which pumps from a large container of premixed citric acid on the plant room floor. The generator will heat the acid so the reaction speeds up, it will drain down at the end of the cycle, you can choose how long you want the descale cycle to last but we advise no shorter than 4 hours. The generator will descale itself on the same day and time every week unless this option is turned off. 120litre and 25 litre containers are available from our website to store the liquid descaling solution.
SAFETY FEATURES
Thermal overload cut out, boil dry protection and pressure relief valve are all included on every steam generator.
STEAM ON DEMAND FUNCTION
The steam on-demand button can be located inside or outside the steam room for the customers to operate. Once pressed the generator delivers steam for 30 minutes and then stops until the button is pressed again saving energy, extending generator life and reducing costs during quieter periods of operation.
AUTO DESCALE
To ensure long life of a commercial steam generator running continuously throughout the day the auto descale feature is essential. From the keypad you can choose which day and time you want the descaling cycle to take place (for example Sunday 00:00 - 7:00). The generator is supplied with a pump which pumps from a large container of premixed citric acid on the plant room floor. The generator will heat the acid so the reaction speeds up, it will drain down at the end of the cycle, you can choose how long you want the descale cycle to last but we advise no shorter than 4 hours. The generator will descale itself on the same day and time every week unless this option is turned off. 120litre and 25 litre containers are available from our website to store the liquid descaling solution.
TWIN STEAM NOZZLE
OCD generators have two steam outlets and are supplied with high visibility nozzles for use in commercial environment.
LARGE BORE DRAIN VALVE
We have increased the size of the drain valve and given it an easy access cap to allow easy cleaning of any limescale deposits.
LCD CONTROL PANEL
The OCD generator is supplied with a programmable LCD display with detailed diagnostics. Program your steam generator to automatically turn on and off multiple times during the day.
| Dimensions | 610 x 300 x 585 |
|---|